Table 7-4. Error Codes - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Advanced Energy

Table 7-4. Error Codes

Error Code and
Message
Master/Slave Fault
(See the "Error E081
Fault Vector" section
(explicit clear)
Master of Slave Fault
Occurred
Master/Slave
Parameterization Fault
Master/Slave Fault
Occurred
Output On: Cannot Add/
Rename Slave
7-14
Page 168 of 182
®
Problem Indicated
E081
An error occurred while the
Master/Slave system was
running.
below)
E082
The Pinnacle Master/Slave
system failed to initialize
properly.
E083
An error occurred in the
master/slave system.
E084
The processor detected an
error and turned off the output
from the Master/Slave
system.
E085
The action can not be
performed while output is on.
Troubleshooting and Customer Support
Suggested Action
If you have a Pinnacle
Remote Active Panel or an
active front panel, the error
message should be displaying
a fault vector. The fault vector
is described in the following
section. If consulting this
information fails to indicate a
solution or if you do not have
an active front panel or a
Pinnacle Remote Active
Panel, power off the unit and
ensure that cables are
properly connected and that
the Master/Slave selection
switch is set properly; then
power the unit back on. (See
the "Installation" chapter for
more information about
Master/Slave cabling and
switches.)
Call AE Global Support.
Check the master/slave setup,
and power the unit off and
then back on. If the error
persists, call AE Global
Support.
Power the unit off and then
back on. If the error persists,
call AE Global Support.
Turn output off and repeat
this action. If the problem
persists, call AE Global
Support.
5702199-A