Checking The Number Of Cycles; Debugging Your Unit; Checking Your Master/Slave System - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Advanced Energy
– POWER displays the number of line power faults.
– OVRTMP displays the number of over temperature faults.
– BUS displays the number of bus faults.
– INVRTR displays the number of inverter faults.
5. If you press INTRLOCK, the number of contactor, user, and cable faults appears.
6. If you press IRQ, the number of predefined and unassigned IRQs appears.
7. If you press MONITOR, you can check the number of setpoint timer faults and process
voltage faults.
8. If you press DSP, the number of DSP control and DSP watch dog faults appears.

CHECKING THE NUMBER OF CYCLES

To check the cycles, follow these steps:
1. Press SERVICE → STATS → EVENTS.
FAULTS and CYCLES options appear.
2. Press the CYCLES soft key.
OUTPUT and UNIT options appear.
3. To get a report of the number of output on events, press the OUTPUT soft key.
4. To get a report of the number of power on events, press UNIT.

Debugging Your Unit

SERVICE → DEBUG
Use this option to check the hardware configuration, installed cards, and logic software
options.

CHECKING YOUR MASTER/SLAVE SYSTEM

SERVICE → DEBUG → SYSTEM
Displays master/slave system size and number of slaves in system.
SERVICE → DEBUG → SYSTEM → FAULTS
Rotate the MODIFY knob to display master faults and slave faults individually. Use this
option to check logic and master/slave card faults on master and slave(s).
SERVICE → DEBUG → SYSTEM → UNITS
Rotate the modify knob to display output power and output current of each unit in the master/
slave system.Use this option to check output levels of individual units in the master/slave
system.
4-24
Page 58 of 182
®
I/O Communication and Control
5702199-A