Chapter 3. Specifications; Functional Specifications; Table 3-1. Functional Specifications - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Specifications

FUNCTIONAL SPECIFICATIONS

The following table lists the functional specifications.

Table 3-1. Functional Specifications

Modes of Control
Passive Panel Options
Method of Output Regulation
Programmable Setpoints
Output Limits
Target Supervision
5702199-A
Page 25 of 182
Pinnacle™ 20 kW
Serial communications (Host) port, User port (analog/
digital interface), active front panel, and/or Pinnacle
Remote Active Panel
Your unit also may feature either a passive front panel
or a remote passive panel.
The regulation mode is the parameter that remains
constant when the Pinnacle is producing output; it can
be power, current, or voltage. Select one of these
regulation modes from the optional Pinnacle Remote
Active Panel, the active front panel, the User port, or the
serial (Host) port.
You can program an output level (from low values up to
the unit's maximum rates of output) for power, current,
or voltage. Select this value from the optional Pinnacle
Remote Active Panel, the active front panel, the User
port, or the serial (Host) port.
You may set maximum output limits for power, voltage,
and current. You also may select a maximum strike-
voltage range. Select these values from the optional
Pinnacle Remote Active Panel, the active front panel,
the User port, or the serial (Host) port.
You can select one of eight target-life counters from the
active front panel, Pinnacle Remote Active Panel, User
port, or serial (Host) port. Target life can be monitored
from the Pinnacle Remote Active Panel, the active front
panel, and the serial port.
Note: The User port has priority when selecting targets.