Advanced Energy Pinnacle 20 kW Manual page 98

Table of Contents

Advertisement

Advanced Energy
Table 4-18. Host Port Commands
Command
24
calculate
logic crc
25
calculate
front panel
crc
26
joule
threshold
4-64
Page 98 of 182
®
Description
Tells the Pinnacle supply to calculate its
logic crc.
Note: During the approximately 2 s it
takes to calculate the crc, the
Pinnacle unit will not respond to
any other commands.
Read this value back with Command 230.
Tells the Pinnacle supply to calculate the
front panel software crc. Note: During
the approximately 2 s it takes to calculate
the crc, the Pinnacle unit will not respond
to any other commands. Read this value
back with Command 230.
Specifies the output power level that
needs to be met before the Joule output
energy calculation begins. To set the
threshold (in watts), send 2 bytes (16-bit
value) between 10 W and maximum unit
power divided by 8.
Read back this value with command 136.
I/O Communication and Control
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
0
CSR only
0
CSR only
2
0
5702199-A