SLAVE STATUS HIGH BYTE

BIT 7 6 5 4 3 2 1 0
|
| | | |
|
| | | |
|
| | | |
|
| | | |................ Interlock open
|
| | |......................Contactor not closed
|
| |...........................Reserved
|
|...............................Reserved
|.....................................Reserved

PERSONALITY CARD STATUS

BIT 7 6 5 4 3 2 1 0
|
| | | |
|
| | | |
|
| | | |
|
| | | |................ Bad function
|
| | |......................Reserved
|
| |...........................External off received
|
|...............................Slave not responding
|.....................................Dual port ram error
See Table 7-3 on page 7-6 and "Error Code Troubleshooting Table" on page 7-8 to determine
the proper action to take in response to any fault indicated in the status bytes. If you are unsure
how to respond, please contact AE Global Support.
5702199-A
Page 171 of 182
| | | Control circuit fault
| |......Configuration fault
|...........Over-temperature fault
| | | Initialization error
| |......Multiple Masters
|...........Bad address range
Troubleshooting and Customer Support
Pinnacle™ 20 kW
7-17