Table 4-18. Host Port Commands
Command
101
runtime
recipe
setpoint
4-72
Page 106 of 182
®
Description
Send this command to specify a new
setpoint level that is applied during the
execution of a recipe or ramp. The
setpoint takes effect immediately upon
receipt by the power supply and applies
to the step currently executing for which
ever method of regulation is currently
active. See command 6 for the format of
the 2 data byte setpoint value.
If command 101 is issued during a ramp
or the ramp portion of a recipe step, the
power supply output will ramp to the new
setpoint linearly in the ramp time
remaining. The new setpoint will remain
in place for the subsequent run following
the ramp. If the recipe is not finished, the
next ramp will begin at the new setpoint
and ramp to the preprogrammed setpoint
value for the recipe step.
If command 101 is issued during the run
portion of the ramp or recipe step, the
power supply output will immediately
step to the new setpoint.
Command 101 can be issued as many
times as necessary during the execution
of a recipe with different setpoint values
as needed.
The originally programmed recipe values
will not be affected by runtime changes
of the setpoint value with command 101
and will be available for the next recipe
execution.
Note: The user should send command
164 to check the setpoint not command
182 after adjusting the setpoint with
command 101.
I/O Communication and Control
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
2
CSR only
5702199-A