Connecting Output Power; Terminal Block Output Connector - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Advanced Energy

Connecting Output Power

RISK OF DEATH OR BODILY INJURY. Disconnect and Lockout/Tagout all sources
of input power before disconnecting output cables. Disconnect all sources of input
power before working on this unit or anything connected to it.
This unit must be installed so that the input and ouput connections are inaccessible to
the user. Lethal voltages are potentially present once the input connections are
complete. Be sure connectors are terminated and follow normal safety precautions
when the system is operating.
Improper connection to the output connector could hamper operation of the Pinnacle
unit. If you are unsure how to connect your output cable between the Pinnacle unit and
your chamber, please contact AE Customer Support.
To comply with EMI/EMC standards, you must use a shielded output cable and connect
the shield to the ground terminal on the Pinnacle unit's output connector.

TERMINAL BLOCK OUTPUT CONNECTOR

To meet SELV (Safe Extra Low Voltage) requirements, you must tie the positive
output to chamber ground. Do not allow either positive to exceed +/-40 V with respect
to ground.
The output connector for your Pinnacle supply provides two 10-32 studs as ring lug terminals.
A strain relief box is provided with the connector, but the output cable is not provided. With
this connector, we recommend using a UL-type CATVP cable or equivalent.
5-10
Page 138 of 182
®
Installation
5702199-A