Advanced Energy Pinnacle 20 kW Manual page 97

Table of Contents

Advertisement

Table 4-18. Host Port Commands
Command
22
recipe
setpoint
23
recipe run
time
5702199-A
Page 97 of 182
Description
Specifies the setpoint for a recipe step.
Send three data bytes arranged as
follows:
• first byte = recipe step (must be a
value greater than 0 but no greater
than 8)
• second and third bytes = value
between 0 and the full rated output
of the supply, for the regulation
mode set with Command 20. (See
the "Specifications" chapter for your
unit's capabilities and Command 6
for the format of the value).
Read back these values with Command
182.
Specifies the length of time the unit will
run at setpoint for a recipe step. Send 3
data bytes arranged as follows:
• first byte = recipe step (value must
be greater than 0 but no greater than
8)
• second and third bytes = value
between 0 and 60,000 (or between 0
and 600 s); two decimal places
implied.
Note: If unit has the 100 ms device,
one decimal is implied.
Read back these values with Command
183.
Note: If you assign 0 run time for the
final recipe step, the unit will
switch to continuous output when
it reaches setpoint for this step. In
this situation, to turn off output,
you must send an off command
(using the OFF button or the
appropriate User port signal or
serial port command) or you must
have already enabled joule mode
and programmed a joule setpoint.
I/O Communication and Control
Pinnacle™ 20 kW
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
3
CSR only
3
CSR only
4-63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents