Table 4-18. Host Port Commands
Command
12
target life
13
target enable
14
control mode
15
ramp enable
16
ramp time
4-60
Page 94 of 182
®
Description
Sets the life (in kilowatt-hours) of the
target you specify. Send 1 data byte (8-bit
value) plus 4 data bytes (32-bit value),
arranged as follows:
• first byte = the target number
• second/third/fourth/fifth bytes =
target life in kilowatt-hours
Note: Two decimal places are implied
(that is, to get 1 kW, send a value
of 100). Read back this value with
Command 157.
Enables or disables the target life
counter. Send 1 data byte (8-bit value):
• 0 = inactive
• non-zero value = target life is active
Read back this value with Command 163
Chooses the mode of control for the
Pinnacle supply. Send 1 data byte:
• 2 = serial (Host) port
• 4 = User port
• 6 = an active control panel.
Read back this value with Command 155.
Enables or disables the ramp feature.
Send 1 data byte (8-bit value):
• 0 = disable
• non-zero = enable
Read back this value with Command 163
Sets the ramp time in 10 ms increments.
Range is 50 ms to 600.00 s. Send a 2-byte
value between 5 and 60,000.
Note: Two decimal places are implied.
(A value of 100 = 1.00 s.) If the
unit has the 100 ms ramp feature,
one decimal is implied. (A value of
100 = 10.0 s.)
Read back this value with Command 158.
I/O Communication and Control
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
5
CSR only
1
CSR only
1
CSR only
1
CSR only
2
CSR only
5702199-A