Pinnacle™ 20 kW

SELECTING A LOCK CODE

SUPPLY → PANEL→ LOCK
To enter a lock code for locking the active control panel:
1. Press SUPPLY → PANEL → LOCK.
4 SET CODE and LOCK UNIT options appear.
2. To set a lock code, press the SET CODE soft key. If a code is already entered,
press LOCK UNIT.
4 Any further menu accesses will require entry of the code.
Note: Cycling power on the supply resets the lock status to UNLOCKED.

SELECTING THE NUMBER OF CLICKS

SUPPLY → PANEL→ CLICKS
The clicks feature specifies the number of high speed counts per click for the
MODIFY knob. The value you enter is a multiplier for each click of the knob when
you turn the knob quickly. When you turn the knob slowly, the multiplier does not
take effect. You can enter any number from one to 40. If you want a displayed value to
change slowly as you turn the knob, set the number of counts per click to 1. If you
want the value to change quickly, set the number of counts to 40.
To change the number of counts per click:
1. Press SUPPLY → PANEL → CLICKS.
2. Rotate the MODIFY knob to set the number of counts per click.
3. Press ENTER to accept and exit.

Setting the Program Source

SUPPLY → PGM_SRC
The program source (PGM_SRC) feature specifies for each control mode the program
source for regulation mode and setpoint information. For each control mode, if the
program source is set to internal (INT), the Pinnacle supply uses the information for
output regulation mode and setpoint that has been established through either the
Pinnacle Remote Active panel or the standard serial port. If the program source is set
to external (EXT), the Pinnacle supply uses the setpoint and output regulation mode
that has been established through the pins on the User port.
To select the desired source and type:
1. Press SUPPLY → PGM_SRC.
4 HOST, LOCAL, and USER options appear. Press one of these buttons to
toggle between internal and external for that types.
5702156-E
I/O Communication and Control
4-29