Setting Baud Rates And Communication Mode; Host/Pinnacle Communications; Table 4-16. Baud Rate Settings - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Table 4-14. Address Settings
Address
23
24
25
26
27
28
29
30
31

SETTING BAUD RATES AND COMMUNICATION MODE

Also use the DIP switch (see Figure 4-12 on page 4-45 and Figure 4-13 on page 4-45) to set
the serial (Host) port's baud rate. The following tables show the DIP switch settings for BR0,
BR1, and Switch 8. Switch 8 sets the supply to either RS-232 or RS-485/422. Switches BR0
and BR1 set the baud rates.
Table 4-15. Setting Switch 8
Switch Position
down

Table 4-16. Baud Rate Settings

Baud Rate
RS-232
1200
4800
9600
19,200

HOST/PINNACLE COMMUNICATIONS

The following sections describe host/Pinnacle communications.
5702199-A
Page 83 of 182
A4
A3
down
up
down
down
down
down
down
down
down
down
down
down
down
down
down
down
down
down
Communication
Mode
up
RS-232
RS-485/422
Baud Rate
RS-485/422
9600
19,200
38,400
57,600
I/O Communication and Control
A2
A1
down
down
up
up
up
up
up
down
up
down
down
up
down
up
down
down
down
down
BR0
BR1
up
up
up
down
down
up
down
down
Pinnacle™ 20 kW
A0
down
up
down
up
down
up
down
up
down
4-49