Table 4-14. Address Settings
Address
23
24
25
26
27
28
29
30
31
SETTING BAUD RATES AND COMMUNICATION MODE
Also use the DIP switch (see Figure 4-12 on page 4-45 and Figure 4-13 on page 4-45) to set
the serial (Host) port's baud rate. The following tables show the DIP switch settings for BR0,
BR1, and Switch 8. Switch 8 sets the supply to either RS-232 or RS-485/422. Switches BR0
and BR1 set the baud rates.
Table 4-15. Setting Switch 8
Switch Position
down
Table 4-16. Baud Rate Settings
Baud Rate
RS-232
1200
4800
9600
19,200
HOST/PINNACLE COMMUNICATIONS
The following sections describe host/Pinnacle communications.
5702199-A
Page 83 of 182
A4
A3
down
up
down
down
down
down
down
down
down
down
down
down
down
down
down
down
down
down
Communication
Mode
up
RS-232
RS-485/422
Baud Rate
RS-485/422
9600
19,200
38,400
57,600
I/O Communication and Control
A2
A1
down
down
up
up
up
up
up
down
up
down
down
up
down
up
down
down
down
down
BR0
BR1
up
up
up
down
down
up
down
down
Pinnacle™ 20 kW
A0
down
up
down
up
down
up
down
up
down
4-49