• A two-line display, five soft keys, and a MODIFY knob
Figure 4-5. Control panel
Output Power Switches
Use the following switches to turn output power on and off.
ON
OFF
Control Switches
Use the following switches to select the controlling interface.
LOCAL
HOST
USER
5702199-A
Page 51 of 182
Turns on output power if the control panel has control of the on/off
function and all interlock conditions are satisfied.
Turns off output power, no matter which interface is currently
controlling the unit.
Takes back control from the serial port or User port and gives it to the
control panel. If the control panel already has control or output is
turned on, this switch is ignored.
Gives control to the host computer through the serial port no matter
which interface is currently controlling the Pinnacle unit. If the serial
port already has control or output is turned on, this switch is ignored.
Gives control to the controller through the User port no matter which
interface is currently controlling the Pinnacle unit. If the User port
already has control or output is turned on, this switch is ignored.
Note: User control can only be selected when a User Interface Card is
installed in the unit.
I/O Communication and Control
Pinnacle™ 20 kW
4-17