Advanced Energy Pinnacle 20 kW Manual page 105

Table of Contents

Advertisement

Table 4-18. Host Port Commands
Command
80
TCC timer
100
recipe/ramp
hold or
resume
5702199-A
Page 105 of 182
Description
Sets an acceptable idle time during TCC.
When TCC is enabled, the TCC
algorithm executes automatically the first
time output is turned on. If the output,
then, is turned off for less than the
requested idle time, the TCC algorithm
does not execute on the next output on
cycle. If the output is off for longer than
the requested idle time, the TCC
algorithm executes on the next output on
cycle. With this command, send 1 data
byte (an 8-bit value): the value must be
between 0 and 60 and represents seconds.
Read back this value with Command 185.
While a recipe or ramp is executing, this
command provides a means to stop or
restart the recipe or ramp.
• 0 = Resume
• 1 = Hold
I/O Communication and Control
Pinnacle™ 20 kW
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
0
CSR only
1
CSR only
4-71