Table 7-4. Active Panel Display Error Codes (Continued)
Error Code and
Message
E685
Output On: Slave 6
Added/Removed
E782
Slave 7 Fault Occurred
E785
Output On: Slave 7
Added/Removed
E882
Slave 8 Fault Occurred
E885
Output On: Slave 8
Added/Removed
E982
Slave 9 Fault Occurred
E985
Output On: Slave 9
Added/Removed

Error E081 Fault Vector

The master/slave fault vector associated with error code E081 E81 contains three hex
bytes, separated into one two-byte word and a one-byte word (see Command 135 of
the AE Bus command list). The two-byte word is a bit-wise "or" of all the slave unit
errors; thus if a bit is set, the error exists in one or more slaves.
Note: If your Pinnacle master unit features an active panel, you can view error code
information for each slave by turning the MODIFY knob.)
5702156-E
Problem Indicated
The action can not be
performed while output is
on.
Slave 7 failed to initialize
properly.
The action can not be
performed while output is
on.
Slave 8 failed to initialize
properly.
The action can not be
performed while output is
on.
Slave 9 failed to initialize
properly.
The action can not be
performed while output is
on.
Troubleshooting and Customer Support
Suggested Action
Turn output off and repeat
this action. If the problem
persists, call AE Global
Customer Support.
Call AE Global Customer
Support.
Turn output off and repeat
this action. If the problem
persists, call AE Global
Customer Support.
Call AE Global Customer
Support.
Turn output off and repeat
this action. If the problem
persists, call AE Global
Customer Support.
Call AE Global Customer
Support.
Turn output off and repeat
this action. If the problem
persists, call AE Global
Customer Support.