Advanced Energy

Error Code Troubleshooting Table

Use the following table to trouble shoot error codes.
Table 7-4. Active Panel Display Error Codes
Error Code and
Message
E000
Control Circuit Fault
E001
Out of Setpoint Timer
Expired
(explicit clear)
E002
Bus Fault
(explicit clear)
7-8
Problem Indicated
The DSP failed to respond
to the processor.
The out of setpoint timer
has expired.
The buses have failed,
probably due to an AC
input power problem.
Troubleshooting and Customer Support
Suggested Action
Power the unit off and then
back on. If the problem
persists, call AE Global
Customer Support.
Increase the setpoint timer
value or disable the timer
by setting it equal to 0. If
the problem persists, check
your process parameters
for limiting factors. That
is, ensure that your load
impedance matches the
impedance range of the
Pinnacle unit. (See the
"Specifications" chapter
for an impedance range
graph.)
Using all applicable safety
precautions, inspect your
AC input power source to
ensure that it is properly
connected and that the
specified voltage is being
applied to the Pinnacle
unit. (See the
"Specifications" chapter
for AC input power
specifications.)