Installing The Reichle Masari Cross-Connect Terminal (Germany) - Nortel Meridian 1 Succession 1000M Installation And Configuration Manual

Small system
Hide thumbs Also See for Meridian 1 Succession 1000M:
Table of Contents

Advertisement

Installing the Reichle Masari cross-connect terminal
(Germany)
Installing and connecting cross-connect terminals
Procedure 37 describes how to install the Reichle Masari cross-connect
terminal for Germany.
Procedure 37

Installing the Reichle Masari cross-connect terminal (Germany)

1
Consult the equipment layout plan to determine where to place the
cross-connect terminal. Refer to the system and site requirements
Small System: Planning and Engineering (553-3011-120)
chapters in
2
Install the terminal blocks in a layout similar to that shown:
in Figure 97 on
in Figure 97 on
3
Attach labels on the cross-connect terminal to indicate the terminal blocks
assigned to the following:
25-pair cables from the cabinets or chassis
AUX wiring
Power Failure Transfer Units (PFTU)
Telephones and consoles
Trunks
Analog line cards
DC5/AC15/RAN/PAG cards
Data Access Cards
Digital line cards
Exchange line trunk cards
Direct Dialing Inward trunk cards
other miscellaneous equipment
4
For the Cabinet system: Ground the cross-connect terminal.
page 242
for the Cabinet system
page 242
for the Chassis system
Small System
Page 241 of 562