Connecting the cables
Installing and connecting cross-connect terminals
Note: One 25-pair cable contains Card 4 and Card 6 (units 0–7).
Another 25-pair cable contains Card 5 and Card 6 (units 8–15).
WARNING
Always use caution when installing or modifying
telephone lines. Avoid installing telephone wiring during a
lightning storm. Never touch uninsulated telephone wiring
unless the line has been disconnected at the network
interface.
For the Cabinet system:
•
Each cabinet requires up to ten 25-pair cables. Each cabinet requires an
additional terminal block at the cross-connect terminal for the
termination of the 9-pin conductor auxiliary cable.
•
All cables are connected at the bottom of the cabinet and are routed
through the openings in the lower part of the cabinet.
For the Chassis system:
•
Each chassis requires up to five 25-pair cables. The chassis requires an
additional terminal block at the cross-connect terminal to terminate the
9-pin conductor auxiliary cable.
•
Connect all cables at the back of the chassis.
Note: Use caution when using NE-A25B cables with the NTAK02 and
NTAK03 cards. These cables are not wired out to station equipment or
trunk circuits. Do not use the NE-A25B cable with the NTAK10,
NTBK50, or NTAK79 circuit cards.
End of Procedure