Put on the wrist strap provided in the bottom of the cabinet and install the
power supply with the circuit breaker at the OFF position. If this is an ac
powered system, plug in the power supply cord in the commercial power
supply receptacle and into the power supply. Refer to "Installing the power
supplies for the Cabinet system" on
CAUTION WITH ESDS DEVICES
A grounded wrist strap, provided with the cabinet, must
be worn when handling circuit cards to prevent damage
caused by static electricity.
Make sure that the NTDK70 or NTDK78 ac/dc or NTDK72 dc power
supplies are installed and that their circuit breakers are set to OFF.
5
Refer to the ACD Max documentation to complete the installation of the
Max units and related cables.
Connectors for the cables in the expansion cabinet are located on the
panel below the cabinet's shelf. Refer to "Installing and connecting
cross-connect terminals" on
cables to the cabinet.
Note: The slots in the expansion cabinet are labeled 11 through 20. The
corresponding connectors for cables are labeled J11 through J20 or J1
through J10, depending on the type of cabinet.
Installing the Cabinet system
page
159.
page 235
for information about connection
End of Procedure