553-3011-210
Standard 1.00
Installing the Chassis system
12 Install the Small System Controller (SSC) card and the 48-port Digital
Line Card.
a
Install the security device on the NTDK20EA SSC card. Install the
SSC card in CPU slot 0 of the chassis. See "Main cabinet and chassis
NTDK20 SSC card installation" on
b
Install the NTDK16 48-port Digital Line Card in Slot 4 of the
chassis. See Procedure 34 "Installing the NTDK16 48-port Digital
Line Card" on
The NTDK16 Digital Line Card is not required for the Small System
to operate.
13 Install the optional circuit cards that you wish to have in your
Small System. Refer to "Installing optional circuit cards" on
and ISDN Basic Rate Interface: Maintenance (553-3001-518). Also,
refer to your card slot assignment plan.
14 Install the cross-connect terminal. See "Installing and connecting
cross-connect terminals" on
Refer to the following procedures:
— Procedure 36: "Installing the BIX cross-connect terminal" on
page 238
— Procedure 37: "Installing the Reichle Masari cross-connect terminal
(Germany)" on
— Procedure 38: "Installing the Krone Test Jack Frame (UK)" on
page 246
15 Install the cables from the chassis to the cross-connect terminal. See
"Installing and connecting cross-connect terminals" on
to Procedure 40: "Connecting the cables for the Chassis system" on
page
251.
16 Install the PFTUs, if provided. See "Installing Power Failure Transfer
Units" on
page
page
258.
17 Connect the SDI port cable at the back of the chassis. See "Installing and
connecting SDI and Ethernet ports" on
"Connecting SDI ports on the SSC card" on
October 2003
page
232.
page
235.
page 241
257. Refer to Procedure 41: "Installing the PFTU" on
page
191.
page
page
265. Refer to Procedure 42:
page
271.
page 217
235. Refer