Nortel Meridian 1 Succession 1000M Installation And Configuration Manual page 102

Small system
Hide thumbs Also See for Meridian 1 Succession 1000M:
Table of Contents

Advertisement

Page 102 of 562
Figure 27
EMC grounding clip for the chassis
100BaseT cables
secured with a cable tie
553-3011-210
Standard 1.00
Installing the Cabinet system
Figure 28 on
page 103
which the main cabinet of a Cabinet system uses both fiber and IP cabling to
connect two expansion cabinets and one Chassis system (chassis with chassis
expander).
Note: Figure 28 on
configurations using Cabinet systems and Chassis systems.
In this example, the SSC card in the main cabinet of a Cabinet system has one
dual-port Fiber Expansion Daughterboard installed in the top connector and
one single-port IP Daughterboard installed in the bottom connector. The
dual-port Fiber Expansion Daughterboard in the top connector provides card
slots 11–20 and 31–40. The single-port IP Daughterboard in the bottom
connector provides card slots 21–30.
October 2003
Grounding clip
shows an example "mix-and-match" configuration in
page 103
is only an example of one of many possible