1. Stacking pattern is not liner symmetry from both side of pallet, even layer will be
180 degrees turned.
Odd layer
2. Stacking pattern is bilateral symmetry, even layer will be 90 degrees turned.
Odd layer
Load size:
Gives created program's full pallet (loaded pallet) dimension in millimeter. Indication
is displayed Horizontal dimension x Vertical dimension.
Efficiency:
Gives created program's pattern occupation in the pallet in percentage. 90% means
90% of pallet area is occupied by products.
Important!
A 2 axis robot (A700II-P, A1600II-P, BltJr etc.) works at a
2-dimensional plane. For this reason, there is the following
restriction.
1. Stacking type is only column.
2. Standard pattern type is block.
3. Useable stacking option is only "Extra top layer."
4. PY MODE is unusable.
5. Slip sheet is unusable.
Even layer
Even layer
2-13
Over lap
Over lap