6.4.2. One side basis (guide)
You can select the products flow center of the station conveyor or flow one side of
the conveyor. For example, if there is a pusher that registers the entire product
against a guide on the right then the right should be selected. Left or Right is
viewing from as flowing direction (Fixed stop on the end of conveyor is top).
Station width:
When you select the left or right in the guide field, input the conveyor width to
"width" field.
Selection contents for "guide"
funtion
Fixed stopper
Left
Center
corner
Flowing
direction of
product
Input value of "Width" field Guide =Right
Right
corner
Station
conveyor
origin point
Flowing
direction of
product
Input double width for "width" field.
Station width will be "0" if guide is
station origin point.