3. Each test should measure: Open Line (OL)
CONNECT
TEST
METER
LEADS TO:
Battery Charge
Y1, Y2, or Y3
to Ground
Coil
NOTE
Any measurement other than Infinity (open) will indicate
a failed or shorted stator leg.
TEST 3: Measure AC Voltage Output of Each
Stator Leg at Charging RPM
4. Set the selector dial to measure AC Voltage.
5. Start the engine and let it idle.
6. While holding the engine at a specified RPM,
separately measure the voltage across each 'leg' of
the stator by connecting the meter leads to the wires
leading from the alternator (Y1 to Y2, Y1 to Y3, Y2 to
Y3).
9926814 R08 -
Manual
© Copyright Polaris Industries Inc.
7. Refer to the following table for approximate AC
Voltage readings according to RPM. Test each leg at
the specified RPM in the table.
OHMS
READING
8. Example: The alternator current output reading
Open Line
should be approximately 21 VAC at 1300 RPM
(Infinity)
between each 'leg'.
If one or more of the stator leg output AC voltage varies
significantly from the specified value, the stator may
RPM READING
2015-2016 RZR 900
ELECTRICAL
NOTE
need to be replaced.
AC VOLTAGE (VAC)
READING
1300
21 VAC ± 25%
3000
47 VAC ± 25%
5000
79 VAC ± 25%