Obtaining a
Replacement Node
Hard Drive
Figure 45 DXi6900 G1 Node
Hard Drive
Quantum DXi6900 G1 User's Guide
Caution: Powering down the system incorrectly or removing the
wrong drive during a drive failure can result in potential
data loss. Do not power down the system to replace a hard
drive. Make sure you remove the failed drive and not a
good drive.
Before beginning the replacement procedure, make sure that you have
the required replacement kit. The appropriate replacement drive will be
provided by Quantum Customer Support (see
Caution: Always make sure to use Quantum-supplied new drives as
replacement drives. Never insert a drive that was removed
from another system (not even another DXi6900 G1
system).
You will need the following items to perform this procedure:
• Replacement hard drive kit provided by Quantum Customer
Support.
• ESD grounding wrist strap (included in the replacement kit)
Illustration
Chapter 3: FRU Removal and Replacement Procedures
Replacing Node Hard Drives
Figure
45).
Description
Replacement hard drive
for DXi6900 G1 Node
(2.5 inch, 900GB)
PN XRRVX (SED)
PN 8JRN4 (non-SED)
89