Figure 137 Checking Expansion Module Esm Status - Quantum DXi6900 Field Service Manual

With dxi 3.4.0 software
Hide thumbs Also See for DXi6900:
Table of Contents

Advertisement

Chapter 3: FRU Removal and Replacement Procedures
Replacing an Expansion Module ESM Canister
Figure 137 Checking
Expansion Module ESM Status
216
Identifying a Failed Expansion Module ESM
The DXi6900 G1 contains 0–13 Expansion modules (EBODs). Each
Expansion module contains two ESM canisters (A and B).
To identify the failed Expansion module ESM canister:
1 Access the remote management console (see
Management
on page 25).
2 Navigate to the Status > Hardware > Details > Storage Arrays
page.
3 Note the status of the volumes in each Array module (see
Figure
137).
Tray_0 corresponds to the Expansion module (EBOD) connected to
an Array module (RBOD). Tray_99 corresponds to the Array module.
Note: Qarray1 corresponds to RBOD 1 and Qarray2 corresponds
to RBOD 2.
4 Locate the failed ESM canister on the back of the Expansion module
by viewing the Service Action LEDs (see
• Service Action Required - This LED is lit when the component
has failed, but it is not yet in a state to be replaced.
Accessing Remote
Figure
138).
Quantum DXi6900 G1 User's Guide