Figure 122 DXi6900 G1 Array
and Expansion Module Power
Supplies
Figure 123 Array and
Expansion Module Power
Supply LEDs
Quantum DXi6900 G1 User's Guide
Port 1
Port 2
ID/Diag
Use the indicator LEDs on the power supply to identify the failed power
supply (see
Figure
123).
• Standby power (solid green) - Main DC power is off and 5V
standby power is on.
• DC enabled (solid green) - DC power rails are within specified
limits.
• Service action allowed (solid blue) - Safe to remove power supply
from slot.
• Service action required (solid amber) - Power supply has failed
and requires attention.
• AC enabled (solid green) - Power is being applied to the power
supply and the power switch is on.
Standby power
DC enabled
Service action allowed
Chapter 3: FRU Removal and Replacement Procedures
Replacing Array or Expansion Module Power Supplies
Lnk
Lnk
Power supplies
AC enabled
Service action required
199