Chapter 3: FRU Removal and Replacement Procedures
Replacing Array or Expansion Module Power Supplies
Figure 121 DXi6900 G1 Array
Module (RBOD) or Expansion
Module (EBOD) Power Supply
Replacing an Array or
Expansion Power
Supply
198
Illustration
This section describes how to remove and replace a power supply in a
DXi6900 G1 Array module (RBOD) or Expansion module (EBOD). If a
power supply fails, you will be notified by a service ticket in the remote
management console.
Caution: Use appropriate ESD precautions, including the use of a
grounding strap, when performing this procedure.
Removing and replacing a power supply in an Array module (RBOD) or
Expansion module (EBOD) includes the following steps:
•
Identifying a Failed Power Supply in an Array or Expansion Module
•
Removing a Failed Power Supply from an Array or Expansion Module
•
Installing a Replacement Power Supply in an Array or Expansion
Module
Identifying a Failed Power Supply in an Array or Expansion
Module
The DXi6900 G1 Array modules and Expansion modules each contains
two hot-swappable power supplies (see
Description
Replacement power
supply for DXi6900 G1
Array module (RBOD) or
Expansion module
(EBOD)
(585 watt)
PN 9-02213-01
Figure
122).
Quantum DXi6900 G1 User's Guide