Replacing An Array Module Controller - Quantum DXi6900 Field Service Manual

With dxi 3.4.0 software
Hide thumbs Also See for DXi6900:
Table of Contents

Advertisement

Replacing an Array Module Controller

Quantum DXi6900 G1 User's Guide
Installing a Replacement Power Supply in an Array or
Expansion Module
To install the replacement power supply in the DXi6900 G1 Array
module (RBOD) or Expansion module (EBOD):
1 Ensure that the power switch on the new supply is in the off
position (see
Figure
WARNING: To avoid electrical shock, make sure the power cord is
disconnected from the new power supply and the
power switch is off before inserting into the Array or
Expansion module chassis.
2 Slide the replacement power supply into the chassis until the power
supply snaps into place, and push the handles into the closed
position.
3 Connect the power cable to the power supply and plug the cable
into a power outlet.
4 Turn on the power switch.
Allow up to a minute for the system to recognize the power supply
and determine its status. The AC enabled LED turns green to signify
that the power supply is functioning properly.
5 In the remote management console, delete any administrative alerts
and close any service tickets.
This section describes how to remove and replace a controller in a
DXi6900 G1 Array module (RBOD) and contains the following sections:
Obtaining a Replacement Array Module Controller
Replacing an Array Module Controller
Chapter 3: FRU Removal and Replacement Procedures
Replacing an Array Module Controller
124).
201

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxi6900 g1Dxi6900 g2

Table of Contents