Array And Expansion Module Hard Drive Carrier Indicators - Quantum DXi6900 User Manual

With dxi 3.2.5 software
Hide thumbs Also See for DXi6900:
Table of Contents

Advertisement

Chapter 2: Basic Operations
DXi6900 Array and Expansion Modules
Item
Button/LED
3
Over temperature (amber)
4
Power (green)
5
Standby power (green)
Array and Expansion Module Hard Drive Carrier
Indicators
The individual hard drive sleds contain LEDs that indicate the health condition of the hard drive (see
27 below
and
Table 1
below).
Figure 27: Hard Drive Sled LEDs
Table 1:  Hard Drive Sled LEDs
LED 
LEDs off
Drive service action allowed
LED (blue)
Drive fault (amber)
Drive active LED (green)
Caution: Do not remove a hard drive that has not failed. Instead, only remove a drive that has failed. If
you accidentally remove a good drive, wait 30 seconds before reinserting the drive.
Quantum DXi6900 User's Guide
Description 
Indicates the environmental temperature has reached an unsafe
level.
Indicates the enclosure has main power.
Indicates that the enclosure is in standby mode.
1
2
3
Description 
Solid – It is safe to remove the hard drive from the array for service.
Solid – It is safe to remove the hard drive from the array for service.
Solid – The hard drive has failed and a service ticket is created. Contact
Quantum customer support.
Blinking – Drive volume or Array module locate function.
Solid – No activity on the hard drive.
Blinking – There is activity on the hard drive.
Note: It is normal to see drive activity even when the DXi is not reading or
writing data.