Figure 126 Checking Array
Module Controller Status
Quantum DXi6900 G1 User's Guide
Removing and replacing an Array module controller includes the
following steps:
•
Identifying a Failed Array Module Controller
•
Removing a Failed Array Module Controller
•
Installing a Replacement Array Module Controller
Identifying a Failed Array Module Controller
The DXi6900 G1 contains one or two Array modules (RBODs). Each
Array module contains two controllers (A and B).
To identify the failed Array module controller:
1 Access the remote management console (see
Management
on page 25).
2 Navigate to the Status > Hardware > Details > Storage Arrays
page.
3 Note the status of each controller (A and B) in each Array module
(see
Figure
126).
Note: Qarray1 corresponds to RBOD 1, and Qarray2 corresponds
to RBOD 2.
Chapter 3: FRU Removal and Replacement Procedures
Replacing an Array Module Controller
Accessing Remote
203