Quantum DXi6900 Field Service Manual page 195

With dxi 3.4.0 software
Hide thumbs Also See for DXi6900:
Table of Contents

Advertisement

Quantum DXi6900 G1 User's Guide
Note: Ensure that the cables inside the system are routed along
the chassis wall and secured using the cable securing
bracket.
6 Close the Node cover (see
7 Verify that the DXi6900 G1 BIOS settings are set correctly:
Note: The BIOS is automatically updated to the correct Quantum
version when the system boots up. There is no need to
manually update the BIOS, but you must verify that the
BIOS settings are set correctly.
a Turn on the system (see
System
on page 23).
b As the system boots, press F2 to display the System Setup
Main Menu.
c Follow the steps described in
Settings
on page 234 to verify that all BIOS settings are set to
the Quantum required value, and make any changes as needed.
8 Run Factory Detect Hardware from the Service Menu to detect the
new hardware (see
9 In the remote management console, delete any administrative alerts
and close any service tickets.
Updating the Service Tag and Setting the OEM ID
After replacing the system board, you must install the service tag
(specific to the Node) on the replacement system board. This allows the
DXi6900 G1 software to recognize and display the correct service tag on
the Hardware Status page.
In addition, you must run a utility to update the OEM ID. This correctly
sets the system OEM ID to Quantum.
Before you begin, gather the following requirements:
• Bootable USB flash drive
Chapter 3: FRU Removal and Replacement Procedures
Replacing the Node System Board
Opening and Closing the
Turning On and Shutting Down the
Required DXi6900 G1 BIOS
Factory Detect Hardware
Node).
on page 44).