Auxiliary Voltage Detector (Avd); Figure 15. Low Voltage Detector Vs Reset - STMicroelectronics ST72361 Auto Series Manual

8-bit mcu for automotive with flash or rom, 10-bit adc, 5 timers, spi, linsci
Table of Contents

Advertisement

Supply, reset and clock management
The LVD function is illustrated in
Provided the minimum V
the MCU can only be in two modes:
under full software control
in static safe reset
In these conditions, secure operation is always ensured for the application without the need
for external reset hardware.
During a Low Voltage Detector Reset, the RESET pin is held low, thus permitting the MCU
to reset other devices.
Note:
The LVD allows the device to be used without any external RESET circuitry.
The LVD is an optional function which can be selected by option byte.
It is recommended to make sure that the V
device is exiting from Reset, to ensure the application functions properly.

Figure 15. Low voltage detector vs reset

V
IT+
V
IT-
RESET
5.6.2

Auxiliary voltage detector (AVD)

The Voltage Detector function (AVD) is based on an analog comparison between a V
and V
IT+(AVD)
falling voltage is lower than the V
parasitic detection (hysteresis).
The output of the AVD comparator is directly readable by the application software through a
real time status bit (AVDF) in the SICSR register. This bit is read only.
Caution:
The AVD function is active only if the LVD is enabled through the option byte.
Monitoring the V
If the AVD interrupt is enabled, an interrupt is generated when the voltage crosses the
V
IT+(AVD)
In the case of a drop in voltage, the AVD interrupt acts as an early warning, allowing
software to shut down safely before the LVD resets the microcontroller (see
The interrupt on the rising edge is used to inform the application that the V
is over.
If the voltage rise time t
selected by option byte), no AVD interrupt will be generated when V
44/279
value (guaranteed for the oscillator frequency) is above V
DD
V
DD
(LVD)
(LVD)
reference value and the V
main supply
DD
or V
threshold (AVDF bit toggles).
IT-(AVD)
is less than 256 or 4096 CPU cycles (depending on the reset delay
rv
Doc ID 12468 Rev 3
Figure
15.
supply voltage rises monotonously when the
DD
V
hys
main supply. The V
DD
reference value for rising voltage in order to avoid
IT+(AVD)
ST72361xx-Auto
reference value for
IT-(AVD)
Figure
16).
warning state
DD
is reached.
IT+(AVD)
,
IT-(LVD)
IT-(AVD)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ST72361 Auto Series and is the answer not in the manual?

Table of Contents