11. Check if the cut ring can NOT be moved in the longitudinal direction.
The cut ring should be able to turn on the pipe.
12. Retighten the union nut with the same force as for the first assembly. Hold the union body in
place with an open-end wrench in the process.
5.17 Mounting makrofon MX-1
Personnel:
Authorized Distributor
Protective equipment:
Safety gloves
Safety footwear
WARNING Malfunction due to contamination of the horn
The functionality of the makrofon is not ensured if the inside of the horn is contaminated as a result
of the makrofon being mounted in an unsuitable position.
• Mount the makrofon in such a way to ensure that the sound outlet is facing downward.
WARNING Danger of injury due to noise
At operating pressure, the makrofon generates a sound pressure level that can damage human hear-
ing.
• Mount the makrofon in a position that is not in the immediate vicinity of escape routes as much as
is possible.
WARNING Danger of the makrofon malfunctioning
Changes to the makrofon may cause a malfunction in the event of an alarm sounding. This can cause
severe injuries.
• Do not remove or loosen the cylinder screw.