Changing The Product Hose And/Or Air Hose; Cleaning And Replacing The Filter - WAGNER AquaCoat 5010 Translation Of The Original Operating Manual

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
8.2.5

CHANGING THE PRODUCT HOSE AND/OR AIR HOSE

1. Loosen and unscrew clamping screw (1).
2. Loosen nut (2) and remove product hose from
the attachment point.
3. Push protective hose (4) back.
4. Carefully remove product hose (3) from the
protective hose (4).
5. Loosen union nut (5) at gun connection and
carefully remove air hose (6) from the protective
hose (4).
8.2.6

CLEANING AND REPLACING THE FILTER

1. Flush the pump and inline fi lter in accordance with pump's
operating manual. Flush using the gun so that the fl ushing agent
fl ows through the inline fi lter. Maximize the fl ow (remove the
nozzle, open the dosing valve if necessary).
2. Empty the pump in a controlled manner in accordance with
pump's operating manual.
3. Place the grounded collection tank under the inline fi lter.
4. Unscrew the fi lter by turning the handle (4).
5. Remove the fi lter insert (3).
6. If the inline fi lter has any leaks, replace the seal (1).
7. Insert the new fi lter insert (3). Note the installation position:
Closed end in direction of fl ow.
8. If necessary, coat the thread with anti-seize paste (10).
9. Assemble the turning handle (4), inlet housing (2) and outlet
housing (5) and tighten by turning the handle.
10. Fill the pump in accordance with pump's operating manual.
* Filter insert: Order No., see Chapter 14.3.5.
** Anti-sieze paste: Order No., see Chapter 10.3.
ORDER NUMBER DOC 2366600
1
2
3
4
2
1
5
6
B_03546
10 **
3 *
3
4
5
B_05273
98

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquacoat 5020

Table of Contents