WAGNER AquaCoat 5010 Translation Of The Original Operating Manual page 47

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
Hose set
9. Mount hose set on the cabinet in accordance with Chapter 8.2.4 (assembly).
Secure cables and hoses
10. Secure al cables and hoses with cable ties in
the AquaCoat cabinet.
The door switch moves up and down on
the RH cabinet wall. It must be ensured that
no cables and hoses are located within the
travel of the door switch.
Spray gun
11. Mount product hose, air hose and gun cable to spray gun.
2
(sparingly)
SW19
2.5 Nm
Pos
Order No.
2 *
9992698
* Use Vaseline sparingly
Control unit
12. Carefully push the VM 5020W control unit back again to the limit stop. Pay attention to
connecting lines and connecting cables at the back of the control unit!
13. Screw the VM 5020W control unit on the cabinet.
Additional Accessories (option)
14. Mount additional Accessories, if available.
ORDER NUMBER DOC 2366600
SW19
2.5 Nm
2
B_05953
Description
Vaseline white PHHV II
SW19
Air hose
When screwing on the air hose, a second
open-ended/ring spanner must be used
for bracing.
B_05954
Gun cable
47