WAGNER AquaCoat 5010 Translation Of The Original Operating Manual page 51

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
Grounding scheme (example)
B_05896
Signal ground
Minimum cable cross-section
AquaCoat cabinet
Conveyor
Spray booth
Spraying stand
Safe operation of the AquaCoat system is only guaranteed with a grounding connection.
Connect all ground cables using a short and direct route.
Tank
All paints, fl ushing agents and waste tanks have to be made of metal.
All tanks in the cabinet must be connected to the potential equalization.
All further tanks must be grounded.
ORDER NUMBER DOC 2366600
Floor, static dissipative
4 mm²; AWG 12
16 mm²; AWG 6
16 mm²; AWG 6
16 mm²; AWG 6
Conveyor
R
< 1 MΩ
max.
Spraying stand
Signal ground
Work piece