ELECTRICAL DISCHARGE

In the nozzle area of the spray gun electrical discharges can occur. They are completely
non-hazardous for human health. However, they can cause a shock reaction.
Electrical discharge!
Shock reaction.
Danger zone
In order to avoid electrical discharges, a distance
of 100 mm or 4 inches must be maintained from
the work piece and other grounded objects
during and after the spraying process for at least
20 seconds.
ORDER NUMBER DOC 2366600
CAUTION
Maintain a safety distance of 100 mm; 4 inches from the nozzle
area of the spray gun during the spraying process and at least
20 seconds after the end of the spraying process.
A
A
A
A
A = 100 mm
A = 4 inch