EDITION 02/2016
OPERATING MANUAL
8.2.3
SAFETY CHECKS
8.2.3.1
GROUNDING CHECK
Every day
Before starting work, carry out a visual check to ensure that the grounding connection is
present in the AquaCoat cabinet and in all relevant components.
8.2.3.2
INSPECTING THE SAFETY ELEMENTS
Every day
- General visual inspection:
Check for damage or loose contacts:
- black grounding band in the cabinet door,
- black grounding bolt at the cabinet door (below),
- grounding switch on the RH side wall,
- all cables and connections.
Monthly
- Door switch test:
Open the cabinet door.
Switch on the control unit.
Switch air on.
Actuate the trigger on the spray gun.
- Electrical door switch test:
- The high voltage must remain switched off .
- The control unit displays error E30.
- Pneumatic door switch test:
- The grounding switch must remain closed (below).
- Grounding switch test:
Close cabinet door.
Switch on the control unit.
Acoustically ascertain switch movement.
Check that the cabinet door is locked.
Switch off control unit.
Acoustically ascertain switch movement.
ORDER NUMBER DOC 2366600
95