Spraying - WAGNER AquaCoat 5010 Translation Of The Original Operating Manual

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
7.3.3

SPRAYING

1. Secure gun with trigger lock and insert the desired nozzle.
2. Commissioning the system
AirLess spraying
3. Turn atomizing air regulator (11) all the way down.
4. Spray on a test object (pull trigger).
5. Adjust the spray pressure at the product pressure regulator (10) according to the
nozzle and object being sprayed.
AirCoat spraying
6. Open the atomizing air regulator (11) (approx. 0.05 - 0.25 MPa; 0.5 - 2.5 bar; 7 - 36 psi)
and adjust for optimal atomization.
Flat-jet method: Changing the spray jet width
7. Change the spray jet width by selecting the appropriate nozzle.
By turning the air regulation (33), the spray jet can additionally be
adjusted.
Round-jet method
7. By gently turning the nozzle nut (31), the atomizing air jet can
additionally be adjusted.
Do not fully tighten the nozzle nut:
Do not turn the nozzle nut (31) until it is fl ush with the nozzle body (32).
There must be play for the atomizing air between the nozzle nut
and the nozzle body.
The air adjustment (33) at the back of the spray gun does not aff ect the
spray pattern in this process.
Flow rate
8. Product quantity may be able to be reduced by:
- Minimizing the product pressure.
- Using a diff erent size of nozzle (see Accessories).
ORDER NUMBER DOC 2366600
see Chapter 7.3.2.
B_04785
31
32
B_04784
33
67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquacoat 5020

Table of Contents