Grounding - WAGNER AquaCoat 5010 Translation Of The Original Operating Manual

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
6.6

GROUNDING

It is important for systems safety and to achieve an optimum coating that all system
components such as work pieces, conveyors, paint supply, control unit and booth or
spraying stand are perfectly grounded.
Heavy paint mist if grounding is insuffi cient!
Danger of poisoning.
Insuffi cient paint application quality.
A poorly grounded work piece causes:
- very poor wrap-around,
- uneven coating,
- back spraying to the spray gun, i.e., contamination.
Prerequisites for perfect grounding and coating are:
- Clean work piece suspension.
- Grounding of spray booth, conveyor system and suspension on the building side in
accordance with the operating manuals or the manufacturer's information.
- Grounding of all conductive parts within the working area.
- The grounding resistance of the work piece may not exceed 1 MΩ (megaohm) (ground
leakage resistance measured at 500 V or 1000 V).
- Connect the AquaCoat cabinet to the signal ground.
- Connect all ground cables using a short and direct route.
- Safety shoes and gloves, if used, must be static dissipative.
ORDER NUMBER DOC 2366600
WARNING
Ground all device components.
Ground the work pieces to be coated.
50