Secure the spray gun against actuation:
Use the trigger lock (11) to engage the trigger (12).
Note: To secure the entire system, pressure must be relieved as described in Chapter 7.3.4.
5.6.3.2

FUNCTIONING OF THE SPRAY GUN

When the spray gun is connected to the control unit and the
control unit is switched on, the pre-defi ned recipe (R1, R2 or R3)
is shown on the gun display (2) as follows.
Recipe 1
Recipe 2
Recipe 3
Recipe change R1
R2
Press the operating button (4) and hold the button pressed for at
least 2 seconds to go forward 1 recipe.
Display (2)
If the operating key (4) is pressed for 2 seconds, the saved recipe
values for the previously selected recipes numbers will be
reloaded from the memory.
During spraying mode (trigger lever pressed), the status is shown in the display (2) by LEDs.
LED display
LEDs 1 - 3 light up green.
One or both right-hand LEDs illuminate in
orange.
(Warning display: You can continue
working without any limitations.)
ORDER NUMBER DOC 2366600
R3
R1
= Recipe values changed temporarily:
Description
The spray gun is working in an optimal
high-voltage spray current range.
Spray current too high.
Possible causes:
- Spray gun too close to the work piece
- Contamination of the spray gun
2