Faults are indicated by the "Fault" LED (24). In addition the error number is shown in the
display (27). If a fault occurs, the high voltage is switched off immediately. The user can
only continue to work once the fault has been remedied and acknowledged with push
button "Service" (25).
Code
Malfunction
display
E11
Ground monitoring
E12
No coil current/
cascade interrupt
E13
Coil current too big
E21-E25 Exception error
E30
Door switch
E40-E43 Gun communication
faulty
E60
Password error
ORDER NUMBER DOC 2366600
24
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
Cause
- Grounding cable is interrupted
- Gun is not connected
- The cascade is not connected
- Cascade is interrupted
defective
- The cascade is defective
- Hardware defect has occurred
- Door open
- Door switch defective
- Gun cable defective
- Operating unit of spray gun
defective
- Control unit defective
- Password not set
27
POWER
POWER
0
1
AquaCoat
B_03505
Remedy
- Check/replace gun cable
- Check/replace gun
- Connect gun
- Connect the cascade
- Check or replace cascade
- Check or replace cascade
- If problem persists, contact the
WAGNER Service Team
- Close door
- Check/replace door switch
- Check/replace gun cable
- WAGNER Service
- WAGNER Service
- Password to be set by Service
Center