EDITION 02/2016
OPERATING MANUAL
6.5.2
VENTILATION OF THE SPRAY BOOTH
The electrostatic spraying equipment may only be operated in defi ned spraying areas and
in accordance with the EN 12215 standard or under comparable ventilation conditions.
The electrostatic spraying equipment must be locked to the technical ventilation so that
the coating product supply and the high voltage are not eff ective as long as the technical
ventilation is not operated with the minimum exhaust air volume fl ow or a larger exhaust
air volume fl ow.
Ensure that the excess coating product (overspray) will be collected up safely.
Toxic and/or fl ammable vapor mixtures!
Risk of poisoning and burns.
6.5.3
AIR SUPPLY
You must ensure that only dry, clean atomizing air is used in the spray gun. Dirt and
moisture in the atomizing air worsens the spraying quality and spraying pattern.
Hose connections!
Risk of injury and damage to the device.
ORDER NUMBER DOC 2366600
WARNING
Operate the device in a spray booth approved for the working
materials.
-or-
Operate the device on an appropriate spraying wall with the
ventilation (extraction) switched on.
Observe national and local regulations for the exhaust air speed.
WARNING
Do not exchange hose connections of product hose and air hose.
48