7.3.12

SETTING AND SAVING RECIPES

Nominal values for the high voltage (kV) and for the spray current limiter (μA) are stored in
a recipe. As standard, the following values are saved in the factory in the 3 storage places
available for recipes:
Recipe No.
Set value - high voltage in kV
R1
R2
R3
Recipes 1-3 can be selected and saved directly with the program buttons "R1", "R2" and
"R3". Once the recipe required has been called up, the individual coating parameters can
be called up and changed using the corresponding selection buttons (see Chapters 7.3.13,
7.3.14). When a parameter is changed, the LED on the left of the program button goes out
and indicates to the user that a parameter value has been changed.
Rejecting parameter values
To reuse the originally set values, press the program button briefl y. The modifi ed values
are not taken over.
Saving parameter values
However, if the modifi ed values should be saved, press and hold the corresponding
program button for approx. 2 seconds until the LED beside the button starts to fl ash
quickly. The modifi ed values are then saved.
ORDER NUMBER DOC 2366600
Target spray current limiter in μA
70
60
40
100
100
80
77