Spraying Procedure For Aircoat Round Spray; Spraying Procedure For Aircoat Fan Spray - WAGNER AquaCoat 5010 Translation Of The Original Operating Manual

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
5.6.3.3

SPRAYING PROCEDURE FOR AIRCOAT ROUND SPRAY

In the AirCoat procedure, the spray product is atomized at a pressure of 3 - 15 MPa; 30 - 150 bar;
435 - 2,176 psi. The air at 0-0.25 MPa; 0-2.5 bar; 0-36 psi produces a soft jet. The spray jet
diameter can be adjusted by turning the nozzle nut.
Advantages
- Large application volume
- Low fogging tendency
- Good fi nish
- High viscosity products can easily
be applied
- High endurance of the nozzles
- Jet width adjustment
5.6.3.4

SPRAYING PROCEDURE FOR AIRCOAT FAN SPRAY

In the AirCoat procedure, the spray product is atomized at a pressure of 3 - 15 MPa;
30 - 150 bar; 435 - 2,176 psi. With the help of the AirCoat air, with a pressure of 0-0.25 MPa;
0-2.5 bar; 0-36 psi, a soft, fl at spray jet is produced which largely eliminates the problem of
overlapping in the peripheral zones. With shaping air, there is the possibility of reducing
the width of the spray jet.
Advantages:
- Large application volume
- Low fogging tendency
- Good fi nish
- High viscosity products can easily
be applied
- High endurance of the nozzles
- Jet width adjustment
Variable spray jet width
ORDER NUMBER DOC 2366600
AirCoat air
Spray product
AirCoat air
Multi-channel swirl nozzle
Shaping air
B_00020
Atomizing air
Nozzle nut
Spray jet
Air cap
42