OPERATING MANUAL
The AquaCoat spray system must be cleaned and rinsed out every day. The cleaning and
fl ushing agents must be compatible with the working material.
Incompatibility of cleaning/fl ushing agent and working
medium!
Risk of explosion and danger of poisoning by toxic gases.
Flush system
1. Relieve pressure
2. Close atomizing air regulator.
3. Connect the system to the fl ushing agent supply.
4. Open the compressed air supply.
5. Have collecting tray close by and open relief valve.
6. Close the valve again as soon as clean fl ushing agent comes out.
With round jet nozzle fi tted:
7. Use nozzle spanner to loosen nozzle insert by a half turn.
8. Point the spray gun toward the collecting tray and actuate the trigger. Flush the
gun thoroughly as soon as clean fl ushing agent emerges.
9. Relieve pressure
10. Re-tighten the nozzle insert.
11. Remove fl ushing agent supply.
With fl at jet nozzle fi tted:
7.
Dismount AirCoat nozzle and clean separately (see Chapter 7.3.8).
8.
Point the spray gun toward the collecting tray and actuate the trigger.
9.
Flush the gun thoroughly as soon as clean fl ushing agent emerges.
10. Relieve pressure
11. Remove fl ushing agent supply.
Blowing out the air passages of the spray gun
12. Close the pump pressure regulator, switch on the compressed air supply, and open
the atomizing air regulator.
13. Actuate the trigger of the spray gun and thoroughly blow out the air passages.
14. Switch off the compressed air supply.
Clean the outside of the system
15. Clean the spray gun body and remaining AquaCoat components with a cleaning
agent recommended by the lacquer manufacturer and dry with a cloth or blow gun.
Cleaning the nozzle parts
ORDER NUMBER DOC 2366600
WARNING
Examine the compatibility of the cleaning and fl ushing agents
and working media on the basis of the safety data sheets.
Chapter 7.3.4.
Chapter 7.3.4.
Chapter 7.3.4.
See Chapters 7.3.9 and 7.3.10