Commissioning; Aquacoat With Puma 28-40 Or Evomotion - WAGNER AquaCoat 5010 Translation Of The Original Operating Manual

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
6.9.3

COMMISSIONING

6.9.3.1

AQUACOAT WITH PUMA 28-40 OR EVOMOTION 20-30

Check the unit for leaks
1. Place metal tank (14) containing a suitable medium (e.g., fl ushing agent or water) in
the AquaCoat cabinet.
2. Immerse in tank the suction system (13).
3. Clamp the potential equalization line (22) to the product tank (14).
4. To perform a leak test on the entire installation, the pressure is slowly increased step
by step until the maximum pressure as indicated on the type plate for the system
and product pressure generator fi tted is reached.
Puma 28-40: "Pump pressure" regulator up to 0.8 MPa; 8 bar; 116 psi
EvoMotion 20-30: "Pump pressure" regulator up to 0.67 MPa; 6.7 bar; 97 psi
5. Maintain the pressure for 5 minutes and check all connecting parts for leaks.
6. Reduce the pressure, when the seal of the system has been ascertained.
7. Flush system through well
8. Relieve system pressure
9. Secure the spray gun (4) using the trigger lock.
10. Remove fl ushing agent.
Electrical discharge when using coated product tanks!
Risk of injury; product charge not optimal.
ORDER NUMBER DOC 2366600
Chapter 8.1.3.
Chapter 7.3.4.
CAUTION
Ensure that the metal part of the tank is connected to the
potential equalization line (e.g., remove coating from around
the connection point).