EDITION 02/2016
OPERATING MANUAL
7.3.14
SETTING THE CURRENT LIMITATION
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
6
5
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
22
Above the "Current Limitation" button (5) is the "Current Limitation" bar graph display (22).
If the control unit is in the ready position, this light strip shows the set value as a dot.
The current limitation is an adjustable threshold. If this threshold is exceeded, for example,
by the spray gun having approached the object being sprayed, the high voltage is adjusted
downwards until the threshold is no longer exceeded.
The set values for high voltage (40 kV) and for spray current limitation (83 mA) that are
shown in the examples are saved in R2 by pressing and holding for a longer time the recipe
push button (for > 2 seconds).
ORDER NUMBER DOC 2366600
Procedure:
1. Press the "Current Limitation" button (5) to
adjust the limitation of the spray current.
The LED (6) indicates that current limitation
POWER
POWER
0
1
is selected.
AquaCoat
B_03377
27
2. The current limitation can now be
adjusted using the universal rotary
controller (2) between 10 - 100 μA with
a resolution of 1 μA. The corresponding
POWER
POWER
0
1
value is indicated in the LED display (27).
AquaCoat
B_03378
2
79