Protective clothing, including gloves, must comply with EN 1149-5. The measured
insulation resistance must not exceed 100 megohms.
Ensure that there are no ignition sources such as naked fl ames, sparks, glowing wires,
or hot surfaces in the vicinity. Do not smoke.
Ensure that the pipe joints, hoses, equipment parts and connections are permanently,
technically leak-proof:
- Periodic preventative maintenance and service (replacing hoses, checking tightness
strength and connections, etc.)
- Regular monitoring of leaks and defects via visual inspection and odor testing, e.g.,
daily before commissioning, at the end of work or weekly.
In the event of defects, immediately bring the device or system to a stop and arrange
to have repairs carried out immediately.
Grounding
Make sure that the ground and potential equalization of all system parts are performed
reliably and continuously and can withstand the expected stress (e.g., mechanical
stress, corrosion).
4.2

SAFETY INSTRUCTIONS FOR STAFF

Always follow the information in this manual, particularly the general safety instructions
and the warning instructions.
Always follow local regulations concerning occupational safety and accident prevention.
In electrostatics application: Anyone fi tted with a pacemaker must not enter the
high-voltage area!
4.2.1

SAFE HANDLING OF WAGNER SPRAY DEVICES

The spray jet is under pressure and can cause dangerous injuries.
Avoid injection of paint or fl ushing agents:
Never point the spray gun at people.
Never reach into the spray jet.
Before all work on the device, in the event of work interruptions and functional faults:
- Switch off the energy/compressed air supply.
- Relieve pressure from spray guns and devices.
- Secure spray guns against actuation.
- In the event of functional faults, remedy the fault as described in the "Troubleshooting"
chapter.
If needed, the liquid ejection devices must be checked by experts (e.g., WAGNER service
technician) at least every 12 months to ensure they are safe for work in accordance with
the DGUV regulation 100-500.
- For shut down devices, the examination can be suspended until the next start-up.
Carry out the work steps as described in the "Pressure Relief" chapter:
- If pressure relief is required.
- If the spraying work is interrupted or stopped.
- Before the device is cleaned on the outside, checked or serviced.
- Before the spray nozzle is installed or cleaned.
ORDER NUMBER DOC 2366600