Flushing Out Clogged Round Jet Nozzles; Replacing Round Jet Nozzle's Nozzle Insert - WAGNER AquaCoat 5010 Translation Of The Original Operating Manual

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
7.3.5

FLUSHING OUT CLOGGED ROUND JET NOZZLES

1. Use nozzle spanner (2) to loosen nozzle insert (1) by a half turn.
2. Remove the nozzle spanner and briefl y actuate trigger.
3. After fl ushing the nozzle, re-tighten the nozzle insert.
7.3.6

REPLACING ROUND JET NOZZLE'S NOZZLE INSERT

1. Remove nozzle insert (1) using nozzle spanner (2).
2. Assembling new nozzle insert.
ORDER NUMBER DOC 2366600
1/2
1
2
1
2
B_03531
B_03532
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquacoat 5020