EDITION 02/2016
OPERATING MANUAL
7.3.5
FLUSHING OUT CLOGGED ROUND JET NOZZLES
1. Use nozzle spanner (2) to loosen nozzle insert (1) by a half turn.
2. Remove the nozzle spanner and briefl y actuate trigger.
3. After fl ushing the nozzle, re-tighten the nozzle insert.
7.3.6
REPLACING ROUND JET NOZZLE'S NOZZLE INSERT
1. Remove nozzle insert (1) using nozzle spanner (2).
2. Assembling new nozzle insert.
ORDER NUMBER DOC 2366600
1/2
1
2
1
2
B_03531
B_03532